www.anybus.com www.anybus.com
18 19
Anybus X-gateway ControlNet Adapter to
eldbus and Industrial Ethernet
This Anybus X-gateway is a bridge between a ControlNet
network and any other network from another PLC
vendor.
X-gateways are designed for use in industrial automaon
plants where many dierent networks are used. They copy
cyclic I/O data in both direcons enabling a consistent
informaon ow throughout the enre plant.
Anybus
®
X-gateway™ - Network to network gateways
Connecting a ControlNet network to any other
eldbus or Industrial Ethernet network
When to use
Interconnecng PLC systems and
networks from similar or dierent
vendors.
Enabling Rockwell Automaon
devices with a ControlNet
interface to parcipate on other
PLC systems and networks.
Coupling/Decoupling dierent
parts of a machine or extending
the physical network distance
within an installaon.
Order information
Network: Part.No
AS-Interface Master AB7823
CANopen Master AB7303
Modbus-TCP Master AB9003
PROFIBUS Master AB7803
CANopen Slave AB7838
CC-Link Slave AB7871
ControlNet Adapter AB7864
DeviceNet Adapter AB7855
EtherNet/IP Adapter AB7834
EtherCAT Slave AB7687
Interbus Slave AB7866
Interbus Fiber Opc AB7867
Lonworks AB7872
Modbus Plus Slave AB7870
Modbus RTU Slave AB7869
Modbus-TCP Slave AB7636
PROFIBUS Slave AB7845
PROFIBUS IO Device AB7654
PROFINET IRT Device AB7941
ControlNet Network
PLC
Example: PROFINET Network
Anybus X-gateway
Interface 1: ControlNet Adapter
Interface 2: PROFINET I/O Device
This X-gateway provides one communicaon
interface with ControlNet Adapter/Slave funconality. The second
interface can be a choice of 14 other industrial networks (Master/
Slave) including, CANopen, Modbus, PROFIBUS, PROFINET, EtherCAT
and more.
• An easy way to transmit I/O data between a ControlNet network
and any other industrial network
• Interconnects Rockwell PLC systems with other PLC types
• Fast I/O data transfer with average ming between
networks: 10-15 ms (approx 5 ms Modbus-TCP Master versions)
• Included Anybus OPC server and IT funcons such as web
browser, e-mail and FTP client for versions supporng PROFINET
and Modbus-TCP
• I/O data conguraon via on-board interface or via the free and
included Anybus Conguraon Manager
• Get up-and-running quickly, no programming skills required
• Robust stand-alone metal housing with CE and
C
UL
US
cercaons
Conguration
ControlNet I/O data size and other
network conguraons can be made
in various ways depending on the
X-gateway version selected.
When to use
Interconnecng PLC systems and
networks from similar or dierent
vendors.
Enabling Rockwell Automaon
devices with a DeviceNet interface
to parcipate on other PLC
systems and networks.
Coupling/Decoupling dierent
parts of a machine or extending
the physical network distance
within an installaon.
Order information
Network: Part.No
AS-Interface Master AB7822
CANopen Master AB7302
Modbus-TCP Master AB9002
PROFIBUS Master AB7802
CANopen Slave AB7859
CC-Link Slave AB7862
ControlNet Adapter AB7855
DeviceNet Adapter AB7854
EtherNet/IP Adapter AB7833
EtherCAT Slave AB7686
Interbus Slave AB7857
Interbus Fiber Opc AB7858
Lonworks AB7863
Modbus Plus Slave AB7861
Modbus RTU Slave AB7860
Modbus-TCP Slave AB7635
PROFIBUS Slave AB7844
PROFINET IO Device AB7653
PROFINET IRT Device AB7940
Anybus X-gateway DeviceNet Adapter to
eldbus and Industrial Ethernet
Anybus
®
X-gateway™ - Network to network gateways
Connecting a DeviceNet network to any other
eldbus or Industrial Ethernet network
DeviceNet Network
PLC
Modbus-TCP Master
Example: Modbus-TCP Network
Anybus X-gateway
Interface 1: DeviceNet Adapter
Interface 2: Modbus-TCP Slave
This X-gateway provides one communicaon interface with DeviceNet
Adapter/Slave funconality. The second interface
can be a choice of 14 other industrial networks (Master/Slave) includ-
ing, CANopen, Modbus, PROFIBUS, PROFINET, EtherCAT and more.
• An easy way to transmit I/O data between a
DeviceNet network and any other industrial network
• Interconnects Rockwell PLC systems with other PLC types
• Fast I/O data transfer with average ming between
networks: 10-15 ms (approx 5 ms with CANopen and
Modbus-TCP Master versions)
• Included Anybus OPC server and IT funcons such as web
browser, e-mail and FTP client for versions supporng PROFINET
and Modbus-TCP
• I/O data conguraon via on-board interface or via the free and
included Anybus Conguraon Manager
• Get up-and-running quickly, no programming skills required
• Robust stand-alone metal housing with CE and
C
UL
US
cercaons
This Anybus X-gateway is a bridge between a DeviceNet
network and any other network from another PLC vendor.
X-gateways are designed for use in industrial automaon
plants where many dierent networks are used. They copy
cyclic I/O data in both direcons enabling a consistent
informaon ow throughout the enre plant.
Network Features
DeviceNet Adapter Features
1 = Network connector, 2 = Baud rate, 3 = I/O data,
4= Other
DeviceNet
1 = 5*5.08 PLUG 2 = 125-500 kbit/s
3 = 512 byte IN/OUT
4 = Bit-strobed, Change-of-state or
Cyclic I/O
*See page 53 for mechanical and technical
specicaons
PLC 5 DeviceNet Scanner
ControlNet
1 = 2*BNC Coax + RJ45 (NAP)
2 = 5 Mbit/s 3 = 450 byte IN/OUT
4 = Communications adapter, prole
n.12
*See page 53 for mechanical and technical
specicaons
Network specic features
1 = Network connector, 2 = Baud rate, 3 = I/O data, 4 = Other
ControlLogix PLC
ControlNet Scanner
Conguration
DeviceNet I/O data size and other
network conguraons can be made
in various ways depending on the
X-gateway version selected.
NETWORK TO NETWORK GATEWAYS
Using the Rockwell
Automaon Integrated
Architecture Builder (IAB),
engineers can integrate the
X-gateway making it easy to include in
your network system design.
Using the Rockwell
Automaon Integrated
Architecture Builder (IAB),
engineers can integrate the
X-gateway making it easy to include in
your network system design.
Commentaires sur ces manuels