I/O Modules
566
35013379 02 October 2007
I/O Map Status
Byte
The I/O map status byte is used for the 140AMM09000 Combination module as
follows.
Module Zoom
Selections
Module Zoom selection screens for selecting input ranges and output timeout states
are as follows.
Module Zoom
Selections
(Inputs)
Push <Enter> to display and select the data format for the module and the ranges
for the individual input channels.
Channel 1 output broken wire
Channel 2 output broken wire
Not used
Not used
Channel 1 input out of range or broken wire (4-20 mA)
Channel 2 input out of range or broken wire (4-20 mA)
Channel 3 input out of range or broken wire (4-20 mA)
Channel 4 input out of range or broken wire (4-20 mA)
12345678
Data Formats (per node)
(Inputs)
Channel X Range
(per channel)
(Inputs)
16-bit Format
Voltmeter
12-bit Format
Not installed
-10V to +10V
0V to +10V
-5V to +5V
0V to +5V
1V to +5V
-20mA to +20mA
0mA to +20mA
+4mA to +20mA